TEMPEST High Performance 1U Computer for Secure Communications & Computing.
Key Features:
- TEMPEST Level B (DTM).
- MIL-STD-810G (DTM).
- DEF STAN 59-411 (DTM).
- 2 x LAN, 2x USB, VGA.
- Customisable Design.
- 0°C to 50°C Operating Temperature.
Overview:
Designed to meet TEMPEST standards SDIP 27 (Level B), the TR-1000 small 1U form factor encompasses a powerful specification that ensures protection against unintended electromagnetic emission.
Contact For Price
- Please Contact For Lead Time
Technical Support
- Documentation & Drivers
- Need Help?
- Talk to a solution specialist we're here to make sure you get your right fit solution.
- +44 (0)1527 512400
- computers@steatite.co.uk
Specifications
- System
Processor:
6th Generation Intel® Core™ i3 Processor (2.7 GHz).
Chipset:
Skylake.
Memory:
8GB DDR4 Memory.
Storage:
128GB SSD.
Graphics:
Intel® HD Graphics 530.
- I/O
Main Input (IEC 60320 C14).
M6 Earth Stud.
2 x USB 2.0 (Type A Connectors).
VGA (15 Way High Density D Socket).
2 x LAN (RJ-45 Sockets—10/100/1000).
- Power
Input:
90 – 264V AC, 3 / 1.5A, 47 – 63Hz.
Consumption:
35W Idle (Desktop).
56W Max 100% CPU Load.
- Environmental
Operation Temperature:
0°C to +50°C (30% to 75% RH).
Storage Temperature:
-10°C to +70°C (Up to 95% RH).
Pressure:
Operational 80 mbar Above Standard Atmospheric Pressure.
Vibration:
In Accordance With MIL-STD 810G Method 514.7; 4.5.2 Procedure 1 – General Vibration.
Packaged:
5Hz to 150Hz, Lesser of +/-6mm or +/-2g, 3 Mutually Perpendicular Axes, 1 Octave / Minute, 2 Hours In Each Axis.
Operational:
5Hz to 33Hz, 0.125mm Peak, 3 Mutually Perpendicular Axes, 1 Octave / Minute, 2 Hours In Each Axis.
Shock:
In Accordance With MIL-STD 810G Method 516.7.
Operational:
Half-sine, 15g, 25mS, 3 shocks in each direction of 3 mutually perpendicular axes.
Survival (Operate After):
Half-sine, 20g, 23mS, 3 shocks in each direction of 3 mutually perpendicular axes.
Safety:
BS EN 60950-2006 +A2:2013.
Emissions:
Conducted Emissions EN55032, A1, A2, Class B.
Radiated Emissions EN55032, A1, A2, Class B.
Immunity:
Electrostatic Discharge Immunity EN61000-4-2.
Radiated RF Immunity EN61000-4-3.
Transient Immunity EN61000-4-4.
Surges EN61000-4-5.
Conducted Immunity EN61000-4-6.
AC Voltage Dips EN61000-4-11.
Mains Harmonics EN61000-3-2.
TEMPEST:
Products from this range have been designed to meet SDIP 27 Level B.
- Mechanical
Dimensions (D x W x H):
530 x 430.5 x 43.66 mm (Excluding Handles).
Weight:
Approximately 5.6 kg.
- Other Features
Optical Drive:
DVD RW Drive (Behind Screened Access Panel).
Front Panel Controls:
Power Button (Illuminated).
Reset Switch.
OS Support:
Windows 10.
Need a Custom Solution?
Get in touch with our technical specialists to discuss your specific requirements and see if we can offer a solution.