TEMPEST High Performance 1U Computer for Secure Communications & Computing.
- TEMPEST Level B (DTM).
- MIL-STD-810G (DTM).
- DEF STAN 59-411 (DTM).
- 2 x LAN, 2x USB, VGA.
- Customisable Design.
- 0°C to 50°C Operating Temperature.
Designed to meet TEMPEST standards SDIP 27 (Level B), the TR-1000 small 1U form factor encompasses a powerful specification that ensures protection against unintended electromagnetic emission.
- Processor
-
6th Generation Intel® Core™ i3 Processor (2.7 GHz).
- Chipset
-
Skylake.
- Memory
-
8GB DDR4 Memory.
- Storage
-
128GB SSD.
- Graphics
-
Intel® HD Graphics 530.
- I/O
-
Main Input (IEC 60320 C14).
M6 Earth Stud.
2 x USB 2.0 (Type A Connectors).
VGA (15 Way High Density D Socket).
2 x LAN (RJ-45 Sockets—10/100/1000).
- Expansion
-
N/A.
- Other Features
-
Optical Drive:
DVD RW Drive (Behind Screened Access Panel).Front Panel Controls:
Power Button (Illuminated).
Reset Switch.
- Power
-
Input:
90 – 264V AC, 3 / 1.5A, 47 – 63Hz.Consumption:
35W Idle (Desktop).
56W Max 100% CPU Load.
- Environmental
-
Operation Temperature:
0°C to +50°C (30% to 75% RH).Storage Temperature:
-10°C to +70°C (Up to 95% RH).Pressure:
Operational 80 mbar Above Standard Atmospheric Pressure.Vibration:
In Accordance With MIL-STD 810G Method 514.7; 4.5.2 Procedure 1 – General Vibration.Packaged:
5Hz to 150Hz, Lesser of +/-6mm or +/-2g, 3 Mutually Perpendicular Axes, 1 Octave / Minute, 2 Hours In Each Axis.Operational:
5Hz to 33Hz, 0.125mm Peak, 3 Mutually Perpendicular Axes, 1 Octave / Minute, 2 Hours In Each Axis.Shock:
In Accordance With MIL-STD 810G Method 516.7.Operational:
Half-sine, 15g, 25mS, 3 shocks in each direction of 3 mutually perpendicular axes.Survival (Operate After):
Half-sine, 20g, 23mS, 3 shocks in each direction of 3 mutually perpendicular axes.
- OS Support
-
Windows 10.
- Dimensions
-
(D) 530 x (W) 430.5 x (H) 43.66 mm (Excluding Handles).
- Weight
-
Approximately 5.6 kg.
- Certification
-
Safety:
BS EN 60950-2006 +A2:2013.Emissions:
Conducted Emissions EN55032, A1, A2, Class B.
Radiated Emissions EN55032, A1, A2, Class B.Immunity:
Electrostatic Discharge Immunity EN61000-4-2.
Radiated RF Immunity EN61000-4-3.
Transient Immunity EN61000-4-4.
Surges EN61000-4-5.
Conducted Immunity EN61000-4-6.
AC Voltage Dips EN61000-4-11.
Mains Harmonics EN61000-3-2.TEMPEST:
Products from this range have been designed to meet SDIP 27 Level B.
TEMPEST 1U 15” 4 Port Keyboard/Video/Mouse (KVM)
- Tempest SDIP 27 Level B
- MIL-STD-810G (DTM)
- 15” 1024 x 768 Display.
TEMPEST High Performance 1U Computer for Secure Communications & Computing.
- TEMPEST Level B (DTM).
- MIL-STD-810G (DTM).
- DEF STAN 59-411 (DTM).
Military Grade Fanless Computer For System Control, Condition Monitoring & Data Acquisition
- DEF STAN 00-35 Shock/Vibe (DTM).
- DEF STAN 59-411 EMC (DTM).
- TEMPEST Level B (DTM).